ANSYS > Case Studies > Optimizing Hydropower Plant Location with IoT: A Case Study of Kawa Engineering Ltd.

Optimizing Hydropower Plant Location with IoT: A Case Study of Kawa Engineering Ltd.

ANSYS Logo
Technology Category
  • Actuators - Hydraulic Actuators
  • Analytics & Modeling - Digital Twin / Simulation
Applicable Industries
  • Cement
  • Renewable Energy
Applicable Functions
  • Product Research & Development
Use Cases
  • Construction Management
  • Virtual Prototyping & Product Testing
About The Customer
Kawa Engineering Ltd., based in Vancouver, Canada, is a provider of engineering consulting services. While their expertise is not limited to any specific field, they primarily focus on the design of hydropower projects. They leverage state-of-the-art computational software, finite element analysis, and computer-aided design to add value to their customers. Their services span from conceptual design to final design and construction management of hydroelectric schemes. Their commitment to harnessing renewable energy sources responsibly and effectively is evident in their work.
The Challenge
Kawa Engineering Ltd. was faced with the challenge of locating a powerhouse close to a waterfall for a client in an area with minimal flood risk. The stakes were high as any occurrence of flooding in the powerhouse would result in significant costs. The ideal location would not only mitigate the risk of flooding but also reduce the need for additional components to protect electrical equipment such as generators, turbines, and switch boxes. Furthermore, the right location would determine the cut and fill required for construction, thereby conserving construction resources.
The Solution
Kawa Engineering Ltd. employed a series of technological solutions to address this challenge. Firstly, they created a model of the riverbed’s surface and shores, near where the powerhouse would be positioned, using data collected via laser scanning. This data was then imported into CAD software and then ANSYS® DesignModeler®. They then used the Eulerian−Eulerian multiphase model in ANSYS CFD to define the interaction between flood water and the ambient air for open channel flow. Transient simulation was employed to determine the initial hydraulic jump from flood-water flow through the waterfall. The CFD simulation was run on a 32-core cluster machine and repeated multiple times using different river conditions to determine the maximum hydraulic jump.
Operational Impact
  • The use of advanced simulation techniques and IoT technology by Kawa Engineering Ltd. resulted in a highly effective solution for the client. The precise location of the powerhouse not only mitigates the risk of flooding but also reduces construction costs. The solution also lessens the need for additional protective components for electrical equipment, further reducing costs and potential risks. The use of such technology also demonstrates Kawa Engineering's commitment to responsible and effective management of renewable energy resources.
Quantitative Benefit
  • The simulation showed that the hydraulic jump would reach a maximum of 170 meters, allowing the powerhouse to be situated at an elevation of not lower than 170 meters within the designated area.
  • The positioning of the powerhouse at this elevation is expected to keep the powerhouse dry, reducing the risk of costly flooding.
  • The strategic location also reduces the need for additional protective components for electrical equipment, thereby reducing construction costs.

Case Study missing?

Start adding your own!

Register with your work email and create a new case study profile for your business.

Add New Record

Related Case Studies.

Contact us

Let's talk!
* Required
* Required
* Required
* Invalid email address
By submitting this form, you agree that IoT ONE may contact you with insights and marketing messaging.
No thanks, I don't want to receive any marketing emails from IoT ONE.
Submit

Thank you for your message!
We will contact you soon.