Technology Category
- Sensors - Flow Meters
- Sensors - Liquid Detection Sensors
Applicable Industries
- Automotive
- Electrical Grids
Applicable Functions
- Product Research & Development
Use Cases
- Microgrid
- Smart Campus
About The Customer
The customer in this case study is the Engine Research Center (ERC) at the University of Wisconsin–Madison. The ERC is a major research and educational institution that investigates the fundamentals and applications of internal combustion (IC) engines. The center has a student research staff that averages about 50 students, half of whom apply and develop computer models for simulating flow and combustion in IC engines. The ERC's work is becoming increasingly complex as government emissions standards become stricter, necessitating the incorporation of more physics into simulations and more geometric details into the grids.
The Challenge
The Engine Research Center (ERC) at the University of Wisconsin–Madison, a leading institution in the study and application of internal combustion (IC) engines, faced significant challenges in grid generation for complex IC engine geometries. These complexities included valved intake and exhaust ports and intricate details like piston/liner crevices. The ERC's work involves the application and development of computer models for simulating flow and combustion in IC engines, with each engine model requiring a computational mesh to solve the turbulence, chemistry, and flow equations that define their problems. As government emissions standards become stricter, the need to incorporate more physics into simulations and more geometric details into the grids has increased. The second major challenge was performing grid resolution studies with these geometrically complex grids once they were built.
The Solution
The ERC adopted ANSYS ICEM CFD Hexa, a tool that can read in from a variety of formats or build from within all the geometric details necessary for the model. This tool's flexible blocking approach made it possible to build a structured mesh that could capture those geometric details. Once the blocking was built, it was easy to vary resolution locally for grid resolution studies. ANSYS ICEM CFD Hexa also had the capability to export the grid to ERC’s solvers. The center has been using ANSYS ICEM CFD Hexa for the past three years, and its usage at the ERC continues to grow, providing a comprehensive solution to their grid generation and resolution challenges.
Operational Impact
Case Study missing?
Start adding your own!
Register with your work email and create a new case study profile for your business.
Related Case Studies.
Case Study
Integral Plant Maintenance
Mercedes-Benz and his partner GAZ chose Siemens to be its maintenance partner at a new engine plant in Yaroslavl, Russia. The new plant offers a capacity to manufacture diesel engines for the Russian market, for locally produced Sprinter Classic. In addition to engines for the local market, the Yaroslavl plant will also produce spare parts. Mercedes-Benz Russia and his partner needed a service partner in order to ensure the operation of these lines in a maintenance partnership arrangement. The challenges included coordinating the entire maintenance management operation, in particular inspections, corrective and predictive maintenance activities, and the optimizing spare parts management. Siemens developed a customized maintenance solution that includes all electronic and mechanical maintenance activities (Integral Plant Maintenance).
Case Study
Hydro One Leads the Way In Smart Meter Development
In 2010, Ontario’s energy board mandated that time-of-use (TOU) pricing for consumers be available for all consumers on a regulated price plan. To meet this requirement, Hydro One needed to quickly deploy a smart meter and intelligent communications network solution to meet the provincial government’s requirement at a low cost. The network needed to cover Hydro One’s expansive service territory, which has a land mass twice the size of Texas, and its customers live in a mix of urban, rural, and remote areas, some places only accessible by air, rail, boat or snowmobile. Most importantly, the network needed to enable future enterprise-wide business efficiencies, modernization of distribution infrastructure and enhanced customer service. To meet these needs, Hydro One conceptualized an end-to-end solution leveraging open standards and Internet Protocols (IP) at all communication levels. The utility drew upon industry leaders like Trilliant to realize this vision.
Case Study
Monitoring of Pressure Pumps in Automotive Industry
A large German/American producer of auto parts uses high-pressure pumps to deburr machined parts as a part of its production and quality check process. They decided to monitor these pumps to make sure they work properly and that they can see any indications leading to a potential failure before it affects their process.